0
TECHNICAL BRIEF

A Theoretical Model of Uniform Flow Distribution for the Admission of High-Energy Fluids to a Surface Steam Condenser

[+] Author and Article Information
J. Wang

G. H. Priestman

Department of Chemical and Process Engineering, The University of Sheffield, Sheffield, S1 3JD, England

D. Wu

School of Mechanical Engineering, East China University of Science and Technology, Shanghai 200237, P.R. China

J. Eng. Gas Turbines Power 123(2), 472-475 (Jan 23, 2001) (4 pages) doi:10.1115/1.1359237 History: Received September 01, 2000; Revised January 23, 2001
Copyright © 2001 by ASME
Your Session has timed out. Please sign back in to continue.

References

Sebald, J. F., Phillips, N. A., and Haman, L. L., 1982, “Recommenced Guidelines for the Admission of High-Energy Fluids to Steam Surface Condenser,” EPRI-CS-2251.
Wang, J., 1995, “Theory of Radial Flow Distributor and Characteristics of a Parallel-Multiple Jet,” Ph.D. thesis, East China University of Science and Technology, Shanghai.
Wang,  J., Ge,  X., and Wu,  D., 1998, “Progress of Flow in Manifold,” Adv. in Mech., 28, No. 3, pp. 392–401 (in Chinese).
Bassiouny,  M. K., and Martin,  H., 1984, “Flow Distribution and Pressure Drop in Plate Heat Exchangers-I: U-Type Arrangement,” Chem. Eng. Sci., 29, No. 4, pp. 693–700.
Chang, Chengfang, Zhu, Zibin, Xu, Maosheng, and Zhu, Bingchen, 1979, “An Investigation of Design on the Uniform Fluid Distribution for Radial Flow Reactors,” J. Chem. Ind. Eng., No. 1, pp. 67–90 (in Chinese).
Jin,  Yong, Yu,  Zhiqing, Su,  Zhufan, and Peng,  Binpu, 1984, “Investigations on Branched Pipe Distributors for Fluidized Beds (II) Determination of Design Parameters for Branched Pipe Distributors,” J. Chem. Ind. Eng., 35, No. 3, pp. 204–213 (in Chinese).

Figures

Grahic Jump Location
The static pressure profile of the main channel for M≥1/4
Grahic Jump Location
The static pressure profile of the main channel for 0<M<1/6
Grahic Jump Location
The effect of changing M on flow pressure
Grahic Jump Location
Perforated pipe distributor
Grahic Jump Location
Control volume near a hole
Grahic Jump Location
The static pressure profile of the main channel for 1/6≤M<1/4

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In