0
research-article

Boundary Layer Flashback in Premixed Hydrogen-Air Flames with Acoustic Excitation

[+] Author and Article Information
Vera Hoferichter

Lehrstuhl für Thermodynamik, Technische Universität München, 85748 Garching, Germany
hoferichter@td.mw.tum.de

Thomas Sattelmayer

Lehrstuhl für Thermodynamik, Technische Universität München, 85748 Garching, Germany
sattelmayer@td.mw.tum.de

1Corresponding author.

ASME doi:10.1115/1.4038128 History: Received August 06, 2017; Revised August 09, 2017

Abstract

Lean premixed combustion is prevailing in gas turbines to minimize nitrogen oxide emissions. However, this technology bears the risk of flame flashback and thermoacoustic instabilities. Thermoacoustic instabilities induce velocity oscillations at the burner exit which, in turn, can trigger flame flashback. This article presents an experimental study at ambient conditions on the effect of longitudinal acoustic excitation on flashback in the boundary layer of a channel burner. The acoustic excitation simulates the effect of thermoacoustic instabilities. Flashback limits are determined for different excitation frequencies characterizing intermediate frequency dynamics in typical gas turbine combustors (100-350 Hz). The excitation amplitude is varied from 0 to 36 % of the burner bulk flow velocity. For increasing excitation amplitude, the risk of flame flashback increases. This effect is strongest at low frequencies. For increasing excitation frequency the influence of the velocity oscillations decreases as the flame has less time to follow the changes in bulk flow velocity. Two different flashback regimes can be distinguished based on excitation amplitude. For low excitation amplitudes flashback conditions are reached if the minimum flow velocity in the excitation cycle falls below the flashback limit of unexcited unconfined flames. For higher excitation amplitudes, where the flame starts to periodically enter the burner duct, flashback is initiated if the maximum flow velocity in the excitation cycle is lower than the flashback limit of confined flames. Consequently, flashback limits of confined flames should also be considered in the design of gas turbine burners as a worst case scenario.

Copyright (c) 2017 by ASME
Your Session has timed out. Please sign back in to continue.

References

Figures

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In