Blood viscosity changes with many pathologic conditions, but its importance has not been fully investigated because the current methods of measurement are poorly suited for clinical applications. The use of viscosity-sensitive fluorescent molecular rotors to determine fluid viscosity in a nonmechanical manner has been investigated recently, but it is unknown how the precision of the fluorescence-based method compares to established mechanical viscometry. Human blood plasma viscosity was modulated with high-viscosity plasma expanders, dextran, pentastarch, and hetastarch. The samples were divided into a calibration and a test set. The relationship between fluorescence emission and viscosity was established using the calibration set. Viscosity of the test set was determined by fluorescence and by cone-and-plate viscometer, and the precision of both methods compared. Molecular rotor fluorescence intensity showed a power law relationship with solution viscosity. Mechanical measurements deviated from the theoretical viscosity value by less than 7.6%, while fluorescence-based measurements deviated by less than 6%. The average coefficient of variation was 6.9% (mechanical measurement) and 3.4% to 3.8% (fluorescence-based measurement, depending on the molecular rotor used). Fluorescence-based viscometry exhibits comparable precision to mechanical viscometry. Fluorescence viscometry does not apply shear and is therefore more practical for biofluids which have apparent non-Newtonian properties. In addition, fluorescence instrumentation makes very fast serial measurements possible, thus promising new areas of application in laboratory and clinical settings.

1.
Harkness
,
J.
, 1971, “
The Viscosity of Human Blood Plasma; Its Measurement in Health and Disease
,”
Biorheology
0006-355X,
8
(
3
), pp.
171
193
.
2.
McGrath
,
M. A.
, and
Penny
,
R.
, 1976, “
Paraproteinemia: Blood Hyperviscosity and Clinical Manifestations
,”
J. Clin. Invest.
0021-9738,
58
(
5
), pp.
1155
1162
.
3.
Wells
,
R.
, 1970, “
Syndromes of Hyperviscosity
,”
N. Engl. J. Med.
0028-4793,
283
(
4
), pp.
183
186
.
4.
Letcher
,
R. L.
,
Chien
,
S.
,
Pickering
,
T. G.
,
Sealey
,
J. E.
, and
Laragh
,
J. H.
, 1981, “
Direct Relationship Between Blood Pressure and Blood Viscosity in Normal and Hypertensive Subjects. Role of Fibrinogen and Concentration
,”
Am. J. Med.
0002-9343,
70
(
6
), pp.
1195
1202
.
5.
McMillan
,
D. E.
, 1982, “
Further Observations on Serum Viscosity Changes in Diabetes Mellitus
,”
Metabolism
0026-0495,
31
(
3
), pp.
274
278
.
6.
Otto
,
C.
,
Ritter
,
M. M.
,
Richter
,
W. O.
,
Minkenberg
,
R.
, and
Schwandt
,
P.
, 2001, “
Hemorrheologic Abnormalities in Defined Primary Dyslipoproteinemias With Both High and Low Atherosclerotic Risks
,”
Metabolism
0026-0495,
50
(
2
), pp.
166
170
.
7.
Ernst
,
E.
,
Matrai
,
A.
,
Schmolzl
,
C.
, and
Magyarosy
,
I.
, 1987, “
Dose-Effect Relationship Between Smoking and Blood Rheology
,”
Br. J. Haematol.
0007-1048,
65
(
4
), pp.
485
487
.
8.
Ernst
,
E.
and
Matrai
,
A.
, 1987, “
Abstention From Chronic Cigarette Smoking Normalizes Blood Rheology
,”
Atherosclerosis
0021-9150,
64
(
1
), pp.
75
77
.
9.
Kaperonis
,
A. A.
,
Michelsen
,
C. B.
,
Askanazi
,
J.
,
Kinney
,
J. M.
, and
Chien
,
S.
, 1988, “
Effects of Total Hip Replacement and Bed Rest on Blood Rheology and Red Cell Metabolism
,”
J. Trauma
0022-5282,
28
(
4
), pp.
453
457
.
10.
Heilmann
,
L.
, 1986, “
Changes in Flow Properties of the Blood in Pregnancy
,”
Zentralbl Gynakol.
0044-4197,
108
(
7
), pp.
393
402
.
11.
Roe
,
P. F.
and
Harkness
,
J.
, 1975, “
Plasma Viscosity in the Elderly
,”
Gerontol. Clin.
0016-8998,
17
(
3
), pp.
168
172
.
12.
Dintenfass
,
L.
, 1989, “
Modifications of Blood Rheology During Aging and Age-Related Pathological Conditions
,”
Aging (Milano)
0394-9532,
1
(
2
), pp.
99
125
.
13.
Tsai
,
A. G.
,
Friesenecker
,
B.
,
McCarthy
,
M.
,
Sakai
,
H.
, and
Intaglietta
,
M.
, 1998, “
Plasma Viscosity Regulates Capillary Perfusion During Extreme Hemodilution in Hamster Skinfold Model
,”
Am. J. Physiol.
0002-9513,
275
(
6 Pt 2
), pp.
H2170
H2180
.
14.
Tsai
,
A. G.
, and
Intaglietta
,
M.
, 2001, “
High Viscosity Plasma Expanders: Volume Restitution Fluids for Lowering the Transfusion Trigger
,”
Biorheology
0006-355X,
38
(
2–3
), pp.
229
237
.
15.
Loutfy
,
R. O.
, 1986, “
Fluorescence Probes for Polymer Free-Volume
,”
Pure Appl. Chem.
0033-4545,
58
(
9
), pp.
1239
1248
.
16.
Law
,
K. Y.
, 1980, “
Fluorescence Probe for Microenvironments: Anomalous Viscosity Dependence of the Fluorescence Quantum Yield of P-N,N-Dialkylaminobenzylidenmalononitrile in 1-Alkanols
,”
Chem. Phys. Lett.
0009-2614,
75
(
3
), pp.
545
549
.
17.
Haidekker
,
M. A.
,
Tsai
,
A. G.
,
Brady
,
T.
,
Stevens
,
H. Y.
,
Frangos
,
J. A.
,
Theodorakis
,
E.
, and
Intaglietta
,
M.
, 2002, “
A Novel Approach to Blood Plasma Viscosity Measurement Using Fluorescent Molecular Rotors
,”
Am. J. Physiol. Heart Circ. Physiol.
0363-6135,
282
(
5
), pp.
H1609
H1614
.
18.
Akers
,
W.
, and
Haidekker
,
M. A.
, 2004. “
A Molecular Rotor As Viscosity Sensor in Aqueous Colloid Solutions
,”
ASME J. Biomech. Eng.
0148-0731,
126
(
3
), pp.
340
345
.
19.
Haidekker
,
M. A.
,
Brady
,
T. P.
,
Chalian
,
S. H.
,
Akers
,
W.
,
Lichlyter
,
D.
, and
Theodorakis
,
E. A.
, 2004, “
Hydrophilic Molecular Rotor Derivatives—Synthesis and Characterization
,”
Bioorg Khim.
0132-3423,
32
, pp.
274
289
.
20.
Perry
,
Robert H.
,
Green
,
Don W.
, and
Maloney
,
James O.
, 1984,
Perry’s Chemical Engineers’ Handbook
,
McGraw-Hill
, New York.
21.
Förster
,
T.
, and
Hoffmann
,
G.
, 1971, “
Effect of Viscosity on the Fluorescence Quantum Yield of Some Dye Systems
,”
Z. Phys. Chem. (Munich)
0044-3336,
75
, pp.
63
76
.
22.
Lakowicz
,
J. R.
1999 in
Principles of fluoreescence spectroscopy
Kluwer Academic∕Plenum
, New York, pp.
1
23
.
23.
Reinhart
,
W. H.
,
Danoff
,
S. J.
,
Usami
,
S.
, and
Chien
,
S.
, 1984, “
Rheologic Measurements on Small Samples With a New Capillary Viscometer
,”
J. Lab. Clin. Med.
0022-2143,
104
(
6
), pp.
921
931
.
24.
Cokelet
,
G. R.
1972 in
Biomechanics: Its Foundations and Objectives
,
Fung
,
Y. C.
,
Perrone
,
N.
, and
Anliker
,
M.
eds.,
Prentice Hall
, Englewood Cliffs, NJ, pp.
63
103
.
25.
Holland
,
J. F.
,
Teets
,
R. E.
,
Kelly
,
P. M.
, and
Timnick
,
A.
, 1977, “
Correction of Right-Angle Fluorescence Measurements for the Absorption of Excitation Radiation
,”
Anal. Chem.
0003-2700,
49
(
6
), pp.
706
710
.
You do not currently have access to this content.