This work describes and presents results from a new three-dimensional whole-body model of human thermoregulation. The model has been implemented using a version of the “Brooks Man” anatomical data set, consisting of 1.3×108 cubic volume elements (voxels) measuring 0.2 cm/side. The model simulates thermoregulation through passive mechanisms (metabolism, blood flow, respiration, and transpiration) and active mechanisms (vasodilatation, vasoconstriction, sweating, and shivering). Compared with lumped or compartment models, a voxel model is capable of high spatial resolution and can capture a level of anatomical detail not achievable otherwise. A high spatial resolution model can predict detailed heating patterns from localized or nonuniform heating patterns, such as from some radio frequency sources. Exposures to warm and hot environments (ambient temperatures of 3348°C) were simulated with the current voxel model and with a recent compartment model. Results from the two models (core temperature, skin temperature, metabolic rate, and evaporative cooling rate) were compared with published experimental results obtained under similar conditions. Under the most severe environmental conditions considered (47.8°C, 27% RH for 2 h), the voxel model predicted a rectal temperature increase of 0.56°C, compared with a core temperature increase of 0.45°C from the compartment model and an experimental mean rectal temperature increase of 0.6°C. Similar, good agreement was noted for other thermal variables and under other environmental conditions. Results suggest that the voxel model is capable of predicting temperature response (core temperature and skin temperature) to certain warm or hot environments, with accuracy comparable to that of a compartment model. In addition, the voxel model is able to predict internal tissue temperatures and surface temperatures, over time, with a level of specificity and spatial resolution not achievable with compartment models. The development of voxel models and related computational tools may be useful for thermal dosimetry applications involving mild temperature hyperthermia and for the assessment of safe exposure to certain nonionizing radiation sources.

1.
Wissler
,
E. H.
, 1985, “
Mathematical Simulation of Human Thermal Behavior Using Whole Body Models
,”
Heat Transfer in Medicine and Biology
,
Plenum
,
New York
, pp.
325
373
.
2.
Stolwijk
,
J. A. J.
, 1970, “
Mathematical Model of Thermoregulation
,”
Physiological and Behavioral Temperature Regulation
,
Thomas
,
Springfield, IL
, pp.
703
721
.
3.
Gordon
,
R. G.
,
Roemer
,
R. B.
, and
Horvath
,
S. M.
, 1976, “
A Mathematical Model of the Human Temperature Regulatory System—Transient Cold Exposure Response
,”
IEEE Trans. Biomed. Eng.
0018-9294,
BME-23
(
6
), pp.
434
444
.
4.
Fiala
,
D.
,
Lomas
,
K. J.
, and
Stohrer
,
M.
, 2003, “
First Principles Modeling of Thermal Sensation Responses in Steady-State and Transient Conditions
,”
ASHRAE Trans.
0001-2505,
109
, pp.
179
186
.
5.
Wainwright
,
P.
, 2000, “
Thermal Effects of Radiation From Cellular Telephones
,”
Phys. Med. Biol.
0031-9155,
45
, pp.
2363
2372
.
6.
Van Leeuwen
,
G. M. J.
,
Lagendijk
,
J. J. W.
,
Van Leersum
,
B. J. A. M.
,
Zwamborn
,
A. P. M.
,
Hornsleth
,
S. N.
, and
Kotte
,
A. N. T. J.
, 1999, “
Calculation of Change in Brain Temperatures Due to Exposure to a Mobile Phone
,”
Phys. Med. Biol.
0031-9155,
44
(
10
), pp.
2367
2379
.
7.
Bernardi
,
P.
,
Cavagnaro
,
M.
,
Pisa
,
S.
, and
Piuzzi
,
E.
, 2000, “
Specific Absorption Rate and Temperature Increases in the Head of a Cellular-Phone User
,”
IEEE Trans. Microwave Theory Tech.
0018-9480,
48
(
7
), pp.
1118
1126
.
8.
Adair
,
E. R.
and
Berglund
,
L. G.
, 1992, “
Predicted Thermophysiological Responses of Humans to MRI Fields
,”
Ann. N.Y. Acad. Sci.
,
649
, pp.
188
200
. 0077-8923
9.
Adair
,
E. R.
, and
Berglund
,
L. G.
, 1986, “
On the Thermoregulatory Consequences of NMR Imaging
,”
Magn. Reson. Imaging
,
4
(
4
), pp.
321
333
. 0730-725X
10.
Adair
,
E. R.
, and
Berglund
,
L. G.
, 1989, “
Thermoregulatory Consequences of Cardiovascular Impairment During NMR Imaging in Warm/Humid Environments
,”
Magn. Reson. Imaging
,
7
(
1
), pp.
25
37
. 0730-725X
11.
Dewhirst
,
M. W.
,
Vujaskovic
,
Z.
,
Jones
,
E.
, and
Thrall
,
D.
, 2005, “
Re-Setting the Biologic Rationale for Thermal Therapy
,”
Int. J. Hyperthermia
0265-6736,
21
(
8
), pp.
779
790
.
12.
Mason
,
P. A.
,
Ziriax
,
J. M.
,
Hurt
,
W. D.
,
Walters
,
T. J.
,
Ryan
,
K. L.
,
Nelson
,
D. A.
,
Smith
,
K. I.
, and
D’Andrea
,
J. A.
, 2000, “
Recent Advances in Dosimetry Measurements and Modeling
,”
Radio Frequency Radiation Dosimetry
,
Kluwer Academic
,
Dordrecht
, pp.
141
155
.
13.
Robb
,
R. A.
, 1999, “
3-D Visualization in Biomedical Applications
,”
Annu. Rev. Biomed. Eng.
1523-9829,
1
, pp.
377
399
.
14.
Collins
,
C. M.
,
Smith
,
M. B.
, and
Turner
,
R.
, 2004, “
Model of Local Temperature Changes in Brain Upon Functional Activation
,”
J. Appl. Physiol.
,
97
(
6
), pp.
2051
2055
. 0021-8987
15.
van Leeuwen
,
G. M.
,
Hand
,
J. W.
,
Lagendijk
,
J. J.
,
Azzopardi
,
D. V.
, and
Edwards
,
A. D.
, 2000, “
Numerical Modeling of Temperature Distributions Within the Neonatal Head
,”
Pediatr. Res.
0031-3998,
48
(
3
), pp.
351
356
.
16.
Van den Berg
,
C. A.
,
Van de Kamer
,
J. B.
,
De Leeuw
,
A. A.
,
Jeukens
,
C. R.
,
Raaymakers
,
B. W.
,
van Vulpen
,
V. M.
, and
Lagendijk
,
J. J.
, 2006, “
Towards Patient Specific Thermal Modelling of the Prostate
,”
Phys. Med. Biol.
,
51
(
4
), pp.
809
825
. 0031-9155
17.
Zhang
,
J.
,
Sandison
,
G. A.
,
Murthy
,
J. Y.
, and
Xu
,
L. X.
, 2005, “
Numerical Simulation for Heat Transfer in Prostate Cancer Cryosurgery
,”
ASME J. Biomech. Eng.
0148-0731,
127
(
2
), pp.
279
294
.
18.
Bernardi
,
P.
,
Cavagnaro
,
M.
,
Pisa
,
S.
, and
Piuzzi
,
E.
, 2003, “
Specific Absorption Rate and Temperature Elevation in a Subject Exposed in the Far-Field of Radio-Frequency Sources Operating in the 10-900-MHz Range
,”
IEEE Trans. Biomed. Eng.
,
50
, pp.
295
304
. 0018-9294
19.
Mason
,
P. A.
,
Hurt
,
W. D.
,
Walters
,
T. J.
,
D’Andrea
,
J. A.
,
Gajsek
,
P.
,
Ryan
,
K. L.
,
Nelson
,
D. A.
,
Smith
,
K. I.
, and
Ziriax
,
J. M.
, 2000, “
Effects of Frequency, Permittivity, and Voxel Size on Predicted Specific Absorption Rate Values in Biological Tissue During Electromagnetic-Field Exposure
,”
IEEE Trans. Microwave Theory Tech.
0018-9480,
48
(
11
), pp.
2050
2058
.
20.
Bernardi
,
P.
,
Cavagnaro
,
M.
,
Pisa
,
S.
, and
Piuzzi
,
E.
, 1998, “
SAR Distribution and Temperature Increase in an Anatomical Model of the Human Eye Exposed to the Field Radiated by the User Antenna in a Wireless LAN
,”
IEEE Trans. Microwave Theory Tech.
0018-9480,
46
(
12
), pp.
2074
2082
.
21.
Snyder
,
W. S.
,
Cook
,
M. J.
,
Nasset
,
E. S.
,
Karhausen
,
L. R.
,
Howells
,
G. P.
, and
Tipton
,
I. H.
, 1974, “
Report of the Task Group on Reference Man
,”
International Commission on Radiological Protection (ICRP) Publication 23
,
Pergamon
,
Oxford
.
22.
Fiala
,
D.
,
Lomas
,
K. J.
, and
Stohrer
,
M.
, 2001, “
Computer Prediction of Human Thermoregulatory and Temperature Responses to a Wide Range of Environmental Conditions
,”
Int. J. Biometeorol.
,
45
(
3
), pp.
143
159
. 0020-7128
23.
Gajsek
,
P.
,
Hurt
,
W. D.
,
Ziriax
,
J. M.
, and
Mason
,
P. A.
, 2001, “
Parametric Dependence of SAR on Permittivity Values in a Man Model
,”
IEEE Trans. Biomed. Eng.
,
48
(
10
), pp.
1169
1177
. 0018-9294
24.
Ackerman
,
M. J.
,
Spitzer
,
V. M.
,
Scherzinger
,
A. L.
, and
Whitlock
,
D. G.
, 1995, “
The Visible Human Data Set: An Image Resource for Anatomical Visualization
,”
Medinfo
,
8
, pp.
1195
1198
. 1569-6332
25.
Silver
,
D.
, and
Gagvani
,
N.
, 2002, “
Reshaping Medical Volumetric Data for Enhanced Visualization
,”
Stud. Health Technol. Inform.
,
85
, pp.
488
493
. 0926-9630
26.
Woodard
,
H. Q.
, and
White
,
D. R.
, 1986, “
The Composition of Body Tissues
,”
Br. J. Radiol.
,
59
, pp.
1209
1218
. 0007-1285
27.
Cooper
,
T. E.
, and
Trezek
,
G. J.
, 1971, “
Correlations of Thermal Properties of Some Human Tissue With Water Content
,”
Aerosp. Med.
,
1
, pp.
24
27
. 0001-9402
28.
Duck
,
F. A.
, 1990,
Physical Properties of Tissue
,
Academic
,
San Diego, CA
.
29.
Leggett
,
R. W.
, and
Williams
,
L. R.
, 1995, “
A Proposed Blood Circulation Model for Reference Man
,”
Health Phys.
,
69
, pp.
187
201
. 0017-9078
30.
Mendlowitz
,
M. J.
, 1948, “
The Specific Heat of Human Blood
,”
Science
,
107
, pp.
97
98
. 0036-8075
31.
Bowman
,
H. F.
,
Cravalho
,
E. G.
, and
Woods
,
M.
, 1975, “
Theory, Measurement, and Application of Thermal Properties of Biomaterials
,”
Annu. Rev. Biophys. Bioeng.
0084-6589,
4
, pp.
43
80
.
32.
Valvano
,
J. W.
, and
Chitsabesan
,
B.
, 1987, “
Thermal Conductivity and Diffusivity of Arterial Wall and Atherosclerotic Plaque
,”
Lasers Life Sci.
0886-0467,
1
(
3
), pp.
219
229
.
33.
White
,
D. R.
, and
Fitzgerald
,
M.
, 1977, “
Calculated Attenuation and Energy Absorption Coefficients for ICRP Reference Man (1975) Organs and Tissues
,”
Health Phys.
,
33
, pp.
73
81
. 0017-9078
34.
Keele
,
C. A.
,
Niel
,
E.
, and
Joels
,
N.
, 1982,
Samson Wright’s Applied Physiology
,
Oxford University Press
,
New York
, p.
67
.
35.
Oscar
,
K. J.
,
Gruenau
,
S. P.
,
Folker
,
M. T.
, and
Rapoport
,
S. I.
, 1981, “
Local Cerebral Blood Flow After Microwave Exposure
,”
Brain Res.
,
204
, pp.
220
225
. 0006-8993
36.
Madsen
,
P. L.
,
Schmidt
,
J. F.
,
Holm
,
S.
,
Jorgensen
,
H.
,
Wildschiodtz
,
G.
,
Christensen
,
N. J.
,
Friberg
,
L.
,
Vorstrup
,
S.
, and
Lassen
,
N. A.
, 1992, “
Mental Stress and Cognitive Performance Do Not Increase Overall Level of Cerebral O2 Uptake in Humans
,”
J. Appl. Physiol.
,
73
(
2
), pp.
420
426
. 0021-8987
37.
Olsen
,
R. W.
,
Hayes
,
L. J.
,
Wissler
,
E. H.
,
Nidaidoh
,
H.
, and
Eberhart
,
R. C.
, 1985, “
Influence of Hypothermia and Circulatory Arrest on Cerebral Temperature Distributions
,”
ASME J. Biomech. Eng.
,
107
, pp.
354
360
. 0148-0731
38.
Samaras
,
T.
,
Krikelas
,
G. I.
, and
Sahalos
,
J. N.
, 2000, “
Electromagnetic Exposure of Mobile Phone Users: Assessment of Temperature Rise in the Tissues
,”
Millenium Workshop on Biological Effects of Electromagnetic Fields
, Heraklion, Crete, Greece.
39.
Gustrau
,
F.
, and
Barh
,
A.
, 2002, “
W-Band Investigation of Material Parameters, SAR Distribution, and Thermal Response in Human Tissue
,”
IEEE Trans. Microwave Theory Tech.
0018-9480,
50
(
10
), pp.
2393
2400
.
40.
Demarco
,
S. C.
,
Lazzi
,
G.
,
Liu
,
W.
,
Weiland
,
J. D.
, and
Humayun
,
M. S.
, 2003, “
Computed SAR and Thermal Elevation in a 0.25 mm 2D Model of the Human Eye and Head in Response to an Implanted Retinal Stimulator. Part I: Models and Methods
,”
IEEE Trans. Antennas Propag.
,
51
(
9
), pp.
2274
2285
. 0018-926X
41.
Cohen
,
M. L.
, 1977, “
Measurement of the Thermal Properties of Human Skin: A Review
,”
J. Invest. Dermatol.
,
69
(
3
), pp.
333
338
. 0022-202X
42.
Williams
,
L. R.
, and
Leggett
,
R. W.
, 1989, “
Reference Values for Resting Blood Flow to Organs of Man
,”
Clin. Phys. Physiol. Meas.
,
10
, pp.
187
217
. 0143-0815
43.
Soto
,
P. F.
,
Herrero
,
P.
,
Kates
,
A. M.
,
Dence
,
C. S.
,
Ehsani
,
A. A.
,
Davila-Roman
,
V.
,
Schechtman
,
K. B.
, and
Gropler
,
R. J.
, 2003, “
Impact of Aging on Myocardial Metabolic Response to Dobutamine
,”
Am. J. Physiol. Heart Circ. Physiol.
,
285
, pp.
H2158
H2164
. 0022-2739
44.
Bowman
,
H. F.
, 1981, “
Heat Transfer and Thermal Dosimetry
,”
J. Microwave Power
,
16
(
2
), pp.
121
133
. 0022-2739
45.
Brengelmann
,
G. L.
, 1989, “
Body Temperature Regulation
,”
Textbook of Physiology: Circulation, Respiration, Body Fluids, Metabolism, and Endocrinology
, Vol.
2
, 21st ed.,
H. D.
Patton
et al.
, eds.,
Saunders
,
Philadelphia, PA
, pp.
1584
1596
.
46.
Young
,
H.
,
Carnochan
,
P.
,
Zweit
,
J.
,
Babich
,
J.
,
Cherry
,
S.
, and
Ott
,
R.
, 1994, “
Evaluation of Copper(II)-Pyruvaldehyde bis (N-4-Methylthiosemicarbazone) for Tissue Blood Flow Measurement Using a Trapped Tracer Model
,”
Eur. J. Nucl. Med.
,
21
(
4
), pp.
336
341
. 0340-6997
47.
Dahn
,
M. S.
,
Lange
,
M. P.
, and
Benn
,
S.
, 1999, “
The Influence of Hepatic Venous Oxygen Saturation on the Liver’s Synthetic Response to Metabolic Stress
,”
Proc. Soc. Exp. Biol. Med.
,
221
, pp.
39
45
. 0037-9727
48.
Deneuville
,
E.
,
Perrot-Minot
,
C.
,
Pennaforte
,
F.
,
Roussey
,
M.
,
Zahm
,
J. M.
,
Clavel
,
C.
,
Puchelle
,
E.
, and
de Bentzmann
,
S.
, 1997, “
Revisited Physicochemical and Transport Properties of Respiratory Mucus in Genotyped Cystic Fibrosis Patients
,”
Am. J. Respir. Crit. Care Med.
,
156
, pp.
166
172
. 1073-449X
49.
Kapin
,
M. A.
, and
Ferguson
,
J. L.
, 1985, “
Hemodynamic and Regional Circulatory Alterations in Dog During Anaphylactic Challenge
,”
Am. J. Physiol.
,
249
, pp.
H430
H437
. 0002-9513
50.
Van den Berg
,
J. W.
, 1975, “
Thermal Conductivity and Heat Transfer of the Human Skin
,”
Thermography, Proc. 1st European Congress
,
N. J. M.
Aarts
et al.
, eds.,
Karger
,
Basel
, pp.
166
177
.
51.
Jonsson
,
O.
,
Widmark
,
A.
,
Grankvist
,
K.
,
Damber
,
J. E.
, and
Henriksson
,
R.
, 1992, “
Effects of Clonidine-Induced Hypotension and Dopamine-Induced Hypertension on Blood Flows in Prostatic Adenocarcinoma (Dunning R3327) and Normal Tissues
,”
Prostate
,
20
(
3
), pp.
225
232
. 0270-4137
52.
Barker
,
R. E.
, Jr.
,
Rafoth
,
R. F.
, and
Ward
,
R. W.
, 1972, “
Thermally Induced Stresses and Rapid Temperature Changes in Teeth
,”
J. Biomed. Mater. Res.
,
6
(
5
), pp.
305
325
. 0021-9304
53.
Soyenkoff
,
B. C.
, and
Okun
,
J. H.
, 1958, “
Thermal Conductivity Measurements of Dental Tissues With the Aid of Thermistors
,”
J. Am. Dent. Assoc.
,
57
(
1
), pp.
23
30
. 0002-8177
54.
Adair
,
E. R.
,
Mylacraine
,
K. S.
, and
Cobb
,
B. L.
, 2001, “
Partial-Body Exposure of Human Volunteers to 2450 MHz Pulsed or CW Fields Provokes Similar Thermoregulatory Responses
,”
Bioelectromagnetics
,
22
(
4
), pp.
246
259
.
55.
Adair
,
E. R.
,
Mylacraine
,
K. S.
, and
Cobb
,
B. L.
, 2001, “
Human Exposure to 2450 MHz CW Energy at Levels Outside the IEEE C95.1 Standard Does Not Increase Core Temperature
,”
Bioelectromagnetics
,
22
(
6
), pp.
429
439
.
56.
Adair
,
E. R.
,
Cobb
,
B. L.
,
Mylacraine
,
K. S.
, and
Kelleher
,
S. A.
, 1999, “
Human Exposure at Two Radio Frequencies (450 and 2450 MHz): Similarities and Differences in Physiological Response
,”
Bioelectromagnetics
,
20
(
S4
), pp.
12
20
.
57.
Adair
,
E. R.
,
Kelleher
,
S. A.
,
Mack
,
G. W.
, and
Morocco
,
T. S.
, 1998, “
Thermophysiological Responses of Human Volunteers During Controlled Whole-Body Radio Frequency Exposure at 450 MHz
,”
Bioelectromagnetics
,
19
(
4
), pp.
232
245
.
58.
Pennes
,
H. H.
, 1948, “
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
,”
J. Appl. Physiol.
,
1
, pp.
93
122
. 0021-8987
59.
Werner
,
J.
, and
Buse
,
M.
, 1988, “
Temperature Profiles With Respect to Inhomogeneity and Geometry of the Human Body
,”
J. Appl. Physiol.
,
65
(
3
), pp.
1110
1118
. 0021-8987
60.
McCullough
,
E. A.
,
Jones
,
B. W.
, and
Huck
,
J.
, 1985, “
A Comprehensive Data Base for Estimating Clothing Insulation
,”
ASHRAE Trans.
0001-2505,
91
(
2
), pp.
29
47
.
61.
Nelson
,
D. A.
,
Curlee
,
J. S.
,
Curran
,
A. R.
,
Ziriax
,
J. M.
, and
Mason
,
P. A.
, 2005, “
Determining Localized Garment Insulation Values From Manikin Studies: Computational Method and Results
,”
Eur. J. Appl. Physiol.
,
95
(
5–6
), pp.
464
473
. 1439-6319
62.
Fiala
,
D.
,
Lomas
,
K. J.
, and
Stohrer
,
M.
, 1999, “
A Computer Model of Human Thermoregulation for a Wide Range of Environmental Conditions: The Passive System
,”
J. Appl. Physiol.
,
87
(
5
), pp.
1957
1972
. 0021-8987
63.
ASHRAE
, 2004, “
ANSI/ASHRAE Standard 55–2004: Thermal Environmental Conditions for Human Occupancy
,” Atlanta, GA.
64.
McCullough
,
E. A.
,
Jones
,
B. W.
, and
Tamura
,
T.
, 1989, “
A Data Base for Determining the Evaporative Resistance of Clothing
,”
ASHRAE Trans.
0001-2505,
95
(
2
), pp.
316
328
.
65.
International Organization for Standardization
, 1995, “
ISO 9920: Ergonomics of the Thermal Envioronment—Estimation of the Thermal Insulation and Evaporative Resistance of a Clothing Ensemble
,” ISO 9920.
66.
Curlee
,
J. S.
, 2004, “
An Approach for Determining Localized Thermal Clothing Insulation for Use in an Element Based Thermoregulation and Human Comfort Code
, MS thesis, Michigan Technological University.
67.
Fanger
,
P. O.
, 1970,
Thermal Comfort Analysis and Applications in Environmental Engineering
,
McGraw-Hill
,
New York
.
68.
Stolwijk
,
J. A.
, and
Hardy
,
J. D.
, 1966, “
Partitional Calorimetric Studies of Responses of Man to Thermal Transients
,”
J. Appl. Physiol.
,
21
(
3
), pp.
967
977
. 0021-8987
69.
Fulbrook
,
P.
, 1993, “
Core Temperature Measurement: A Comparison of Rectal, Axillary and Pulmonary Artery Blood Temperature
,”
Intensive Crit. Care Nurs.
,
9
(
4
), pp.
217
225
. 0964-3397
70.
Gagge
,
A. P.
,
Stolwijk
,
J. A.
, and
Hardy
,
J. D.
, 1967, “
Comfort and Thermal Sensations and Associated Physiological Responses at Various Ambient Temperatures
,”
Environ. Res.
,
1
(
1
), pp.
1
20
. 0013-9351
71.
Corry
,
R. T.
,
Longobardo
,
G.
,
Longobardo
,
A. K.
,
Gaillard
,
W. L.
, and
Gaillard
,
W. L.
, Jr.
, 1978, “
Instruments and Controls
,”
Marks’ Standard Handbook for Mechanical Engineers
, Vol.
8
,
McGraw-Hill
,
New York
, Chap. 16.
72.
Schoeller
,
D. A.
, and
Webb
,
P.
, 1984, “
Five-Day Comparison of the Doubly Labeled Water Method With Respiratory Gas Exchange
,”
Am. J. Clin. Nutr.
,
40
(
1
), pp.
153
158
. 0002-9165
73.
Umemiya
,
N.
, 2006, “
Seasonal Variations of Physiological Characteristics and Thermal Sensation Under Identical Thermal Conditions
,”
J. Physiol. Anthropol.
,
25
(
1
), pp.
29
39
. 1880-6791
74.
Gillooly
,
J. F.
,
Brown
,
J. H.
,
West
,
G. B.
,
Savage
,
V. M.
, and
Charnov
,
E. L.
, 2001, “
Effects of Size and Temperature on Metabolic Rate
,”
Science
0036-8075,
293
(
5538
), pp.
2248
2251
.
75.
Haslam
,
R. A.
, and
Parsons
,
K. C.
, 1994, “
Using Computer-Based Models for Predicting Human Thermal Responses to Hot and Cold Environments
,”
Ergonomics
,
37
(
3
), pp.
399
416
. 0014-0139
76.
Durney
,
C. H.
,
Massoudi
,
H.
, and
Iskander
,
M. F.
, 1986, Radiofrequency Radiation Dosimetry Handbook, 4th ed., Report USAFSAM-TR-85–73, USAF School of Aerospace Medicine, Brooks AFB, TX.
You do not currently have access to this content.