Skin marker-based motion analysis has been widely used in biomechanical studies and clinical applications. Unfortunately, the accuracy of knee joint secondary motions is largely limited by the nonrigidity nature of human body segments. Numerous studies have investigated the characteristics of soft tissue movement. Utilizing these characteristics, we may improve the accuracy of knee joint motion measurement. An optimizer was developed by incorporating the soft tissue movement patterns at special bony landmarks into constraint functions. Bony landmark constraints were assigned to the skin markers at femur epicondyles, tibial plateau edges, and tibial tuberosity in a motion analysis algorithm by limiting their allowed position space relative to the underlying bone. The rotation matrix was represented by quaternion, and the constrained optimization problem was solved by Fletcher’s version of the Levenberg–Marquardt optimization technique. The algorithm was validated by using motion data from both skin-based markers and bone-mounted markers attached to fresh cadavers. By comparing the results with the ground truth bone motion generated from the bone-mounted markers, the new algorithm had a significantly higher accuracy (root-mean-square (RMS) error: in axial rotation and in varus-valgus) in estimating the knee joint secondary rotations than algorithms without bony landmark constraints (RMS error: in axial rotation and in varus-valgus). Also, it predicts a more accurate medial-lateral translation (RMS error: ) than the conventional techniques (RMS error: ). The new algorithm, using bony landmark constrains, estimates more accurate secondary rotations and medial-lateral translation of the underlying bone.
Skip Nav Destination
e-mail: nzheng@uncc.edu
Article navigation
December 2010
Technical Briefs
Knee Joint Secondary Motion Accuracy Improved by Quaternion-Based Optimizer With Bony Landmark Constraints
Hongsheng Wang,
Hongsheng Wang
Department of Mechanical Engineering and Engineering Science, Center for Biomedical Engineering Systems,
University of North Carolina at Charlotte
, 9201 University City Boulevard, Charlotte, NC 28223
Search for other works by this author on:
Naiqaun (Nigel) Zheng
Naiqaun (Nigel) Zheng
Department of Mechanical Engineering and Engineering Science, Center for Biomedical Engineering Systems,
e-mail: nzheng@uncc.edu
University of North Carolina at Charlotte
, 9201 University City Boulevard, Charlotte, NC 28223
Search for other works by this author on:
Hongsheng Wang
Department of Mechanical Engineering and Engineering Science, Center for Biomedical Engineering Systems,
University of North Carolina at Charlotte
, 9201 University City Boulevard, Charlotte, NC 28223
Naiqaun (Nigel) Zheng
Department of Mechanical Engineering and Engineering Science, Center for Biomedical Engineering Systems,
University of North Carolina at Charlotte
, 9201 University City Boulevard, Charlotte, NC 28223e-mail: nzheng@uncc.edu
J Biomech Eng. Dec 2010, 132(12): 124502 (6 pages)
Published Online: November 16, 2010
Article history
Received:
July 13, 2010
Revised:
October 13, 2010
Posted:
October 25, 2010
Published:
November 16, 2010
Online:
November 16, 2010
Citation
Wang, H., and Zheng, N. (. (November 16, 2010). "Knee Joint Secondary Motion Accuracy Improved by Quaternion-Based Optimizer With Bony Landmark Constraints." ASME. J Biomech Eng. December 2010; 132(12): 124502. https://doi.org/10.1115/1.4002856
Download citation file:
Get Email Alerts
Simulating the Growth of TATA-Box Binding Protein-Associated Factor 15 Inclusions in Neuron Soma
J Biomech Eng (December 2024)
Effect of Structure and Wearing Modes on the Protective Performance of Industrial Safety Helmet
J Biomech Eng (December 2024)
Sex-Based Differences and Asymmetry in Hip Kinematics During Unilateral Extension From Deep Hip Flexion
J Biomech Eng (December 2024)
Related Articles
A New Subject-Specific Skin Correction Factor for Three-Dimensional Kinematic Analysis of the Scapula
J Biomech Eng (December,2009)
Virtual Axis Finder: A New Method to Determine the Two Kinematic Axes of Rotation for the Tibio-Femoral Joint
J Biomech Eng (January,2010)
Development and Validation of A C0–C7 FE Complex for Biomechanical Study
J Biomech Eng (October,2005)
Related Proceedings Papers
Related Chapters
Manipulability-Maximizing SMP Scheme
Robot Manipulator Redundancy Resolution
A Novel Automated Morphological Fuzzy Optimal Thresholding Technique to Extract Malignant Melanoma Lesions
International Conference on Computer and Computer Intelligence (ICCCI 2011)
A Hybrid Computational Intelligence Algorithm for Automatic Skin Lesion Segmentation in Dermoscopy Images
Intelligent Engineering Systems through Artificial Neural Networks, Volume 20