Cerebral aneurysms constitute a major medical challenge as treatment options are limited and often associated with high risks. Statistically, up to 3% of patients with a brain aneurysm may suffer from bleeding for each year of life. Eight percent of all strokes are caused by ruptured aneurysms. In order to prevent this rupture, endovascular stenting using so called flow diverters is increasingly being regarded as an alternative to the established coil occlusion method in minimally invasive treatment. Covering the neck of an aneurysm with a flow diverter has the potential to alter the hemodynamics in such a way as to induce thrombosis within the aneurysm sac, stopping its further growth, preventing its rupture and possibly leading to complete resorption. In the present study the influence of different flow diverters is quantified considering idealized patient configurations, with a spherical sidewall aneurysm placed on either a straight or a curved parent vessel. All important hemodynamic parameters (exchange flow rate, velocity, and wall shear stress) are determined in a quantitative and accurate manner using computational fluid dynamics when varying the key geometrical properties of the aneurysm. All simulations are carried out using an incompressible, Newtonian fluid with steady conditions. As a whole, 72 different cases have been considered in this systematic study. In this manner, it becomes possible to compare the efficiency of different stents and flow diverters as a function of wire density and thickness. The results show that the intra-aneurysmal flow velocity, wall shear stress, mean velocity, and vortex topology can be considerably modified thanks to insertion of a suitable implant. Intra-aneurysmal residence time is found to increase rapidly with decreasing stent porosity. Of the three different implants considered in this study, the one with the highest wire density shows the highest increase of intra-aneurysmal residence time for both the straight and the curved parent vessels. The best hemodynamic modifications are always obtained for a small aneurysm diameter.
Skip Nav Destination
e-mail: santhosh.seshadhri@st.ovgu.de
e-mail: janiga@ovgu.de
e-mail: oliver.beuing@med.ovgu.de
e-mail: Martin.Skalej@med.ovgu.de
e-mail: thevenin@ovgu.de
Article navigation
July 2011
Research Papers
Impact of Stents and Flow Diverters on Hemodynamics in Idealized Aneurysm Models
Santhosh Seshadhri,
e-mail: santhosh.seshadhri@st.ovgu.de
Santhosh Seshadhri
Laboratory of Fluid Dynamics and Technical Flows, University of Magdeburg “Otto von Guericke”
, Universitätsplatz 2, D-39106 Magdeburg, Germany
Search for other works by this author on:
Gábor Janiga,
e-mail: janiga@ovgu.de
Gábor Janiga
Laboratory of Fluid Dynamics and Technical Flows, University of Magdeburg “Otto von Guericke”
, Universitätsplatz 2, D-39106 Magdeburg, Germany
Search for other works by this author on:
Oliver Beuing,
e-mail: oliver.beuing@med.ovgu.de
Oliver Beuing
Institute for Neuro-Radiology, Medical Department, University of Magdeburg
“Otto von Guericke”, Leipziger Strasse 44, D-39120 Magdeburg, Germany
Search for other works by this author on:
Martin Skalej,
e-mail: Martin.Skalej@med.ovgu.de
Martin Skalej
Professor
Institute for Neuro-Radiology, Medical Department, University of Magdeburg
“Otto von Guericke”, Leipziger Strasse 44, D-39120 Magdeburg, Germany
Search for other works by this author on:
Dominique Thévenin
e-mail: thevenin@ovgu.de
Dominique Thévenin
Professor
Laboratory of Fluid Dynamics and Technical Flows, University of Magdeburg “Otto von Guericke”,
Universitätsplatz 2, D-39106 Magdeburg, Germany
Search for other works by this author on:
Santhosh Seshadhri
Laboratory of Fluid Dynamics and Technical Flows, University of Magdeburg “Otto von Guericke”
, Universitätsplatz 2, D-39106 Magdeburg, Germany
e-mail: santhosh.seshadhri@st.ovgu.de
Gábor Janiga
Laboratory of Fluid Dynamics and Technical Flows, University of Magdeburg “Otto von Guericke”
, Universitätsplatz 2, D-39106 Magdeburg, Germany
e-mail: janiga@ovgu.de
Oliver Beuing
Institute for Neuro-Radiology, Medical Department, University of Magdeburg
“Otto von Guericke”, Leipziger Strasse 44, D-39120 Magdeburg, Germany
e-mail: oliver.beuing@med.ovgu.de
Martin Skalej
Professor
Institute for Neuro-Radiology, Medical Department, University of Magdeburg
“Otto von Guericke”, Leipziger Strasse 44, D-39120 Magdeburg, Germany
e-mail: Martin.Skalej@med.ovgu.de
Dominique Thévenin
Professor
Laboratory of Fluid Dynamics and Technical Flows, University of Magdeburg “Otto von Guericke”,
Universitätsplatz 2, D-39106 Magdeburg, Germany
e-mail: thevenin@ovgu.de
J Biomech Eng. Jul 2011, 133(7): 071005 (9 pages)
Published Online: July 18, 2011
Article history
Received:
January 31, 2011
Revised:
May 12, 2011
Accepted:
May 12, 2011
Online:
July 18, 2011
Published:
July 18, 2011
Citation
Seshadhri, S., Janiga, G., Beuing, O., Skalej, M., and Thévenin, D. (July 18, 2011). "Impact of Stents and Flow Diverters on Hemodynamics in Idealized Aneurysm Models." ASME. J Biomech Eng. July 2011; 133(7): 071005. https://doi.org/10.1115/1.4004410
Download citation file:
Get Email Alerts
Simulating the Growth of TATA-Box Binding Protein-Associated Factor 15 Inclusions in Neuron Soma
J Biomech Eng (December 2024)
Effect of Structure and Wearing Modes on the Protective Performance of Industrial Safety Helmet
J Biomech Eng (December 2024)
Sex-Based Differences and Asymmetry in Hip Kinematics During Unilateral Extension From Deep Hip Flexion
J Biomech Eng (December 2024)
Related Articles
Hydrodynamic Effects of Compliance Mismatch in Stented Arteries
J Biomech Eng (February,2011)
Finite-Element Modeling of the Hemodynamics of Stented Aneurysms
J Biomech Eng (June,2004)
Modeling of Flow in a Straight Stented and Nonstented Side Wall Aneurysm Model
J Biomech Eng (May,1997)
Related Proceedings Papers
Related Chapters
mDFA Human Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)
In-Vitro Modeling of the Dynamic Forces in the Femoropopliteal Artery
Fatigue and Fracture of Medical Metallic Materials and Devices: 2nd Volume
The Quest for Fatigue-Resistant Nitinol for Medical Implants
Fourth Symposium on Fatigue and Fracture of Metallic Medical Materials and Devices