In the section of “Tether Formation from Neutrophils Treated with Cytochalasin D,” the conclusions drawn from comparing cytochalasin-treated neutrophils with passive ones are partly incorrect due to an error in statistical analysis. The correct conclusions should be: for neutrophils treated with 1 μM cytochalasin D, the threshold force is not statistically different from the value for passive neutrophils but the effective viscosity is for neutrophils treated with 100 μM cytochalasin D, both the threshold force and effective viscosity are statistically different from the values for passive neutrophils in both cases). Other conclusions in this section remain the same. Consequently, in the Discussion section, the fourth paragraph should read “Cytochalasin D decreased the effective viscosity to the same level as IL-8 and PMA did. It also decreased the threshold force significantly… . The nonzero threshold force suggests that the neutrophil membrane itself does have a significant contribution to the cortical tension, which is about 24–35 pN/μm for passive neutrophils [11,14].” We regret any inconvenience this may have caused.
Skip Nav Destination
Article navigation
Errata
Erratum: “A Modified Micropipette Aspiration Technique and Its Application to Tether Formation from Human Neutrophils” [ASME J. Biomech. Eng., 124, No. 4, pp. 388–396]
J Biomech Eng. Oct 2004, 126(5): 672 (1 pages)
Published Online: November 23, 2004
Article history
Online:
November 23, 2004
Connected Content
Citation
Shao and , J., and Xu , J. (November 23, 2004). "Erratum: “A Modified Micropipette Aspiration Technique and Its Application to Tether Formation from Human Neutrophils” [ASME J. Biomech. Eng., 124, No. 4, pp. 388–396] ." ASME. J Biomech Eng. October 2004; 126(5): 672. https://doi.org/10.1115/1.1800631
Download citation file:
513
Views
Get Email Alerts
Cited By
Related Articles
Experimentally Tractable, Pseudo-elastic Constitutive Law for Biomembranes: I. Theory
J Biomech Eng (February,2003)
Differential Translocation of Nuclear Factor-KappaB in a Cardiac Muscle Cell Line Under Gravitational Changes
J Biomech Eng (June,2009)
Nanofiber Covered Stent (NCS) for Vascular Diseases
J. Med. Devices (June,2008)
Experimentally Tractable, Pseudo-elastic Constitutive Law for Biomembranes: II. Application
J Biomech Eng (February,2003)
Related Proceedings Papers
Related Chapters
The Data Analysis and Prediction of the Spiritual Comfort Demand of Home Care Security—Based on the Stata Statistical Software Technology and Logit Mode
International Conference on Information Technology and Computer Science, 3rd (ITCS 2011)
Hotspot Identification in Spatial Datasets: A Case Study
International Conference on Computer and Electrical Engineering 4th (ICCEE 2011)
Vibration Analysis of the Seated Human Body in Vertical Direction
International Conference on Computer Technology and Development, 3rd (ICCTD 2011)