One of the most important cycles for electricity generation from geothermal energy is the double-flash cycle. Approximately 25% of the total geothermal based electricity generation all over the world comes from double-flash geothermal power plants. In this paper, performance analysis of a hypothetical double-flash geothermal power plant is performed and variations of fundamental characteristics of the plant are examined. In the performance analysis, initially, optimum flashing pressures are determined, and energy and exergy values of the base points of the plant are calculated. In addition, first and second law efficiencies of the power plant are calculated. Main exergy destruction locations are determined and these losses are illustrated in an exergy flow diagram. For these purposes, it is assumed that a hypothetical double-flash geothermal power plant is constructed in the conditions of western Turkey. The geothermal field where the power plant will be built produces geofluid at a temperature of and a mass flow rate of . According to simulation results, it is possible to produce electrical power output in this field. Optimum first and second flashing pressures are determined to be and , respectively. Based on the exergy of the geothermal fluid at reservoir, overall first and second law efficiencies of the power plant are also calculated to be 6.88% and 28.55%, respectively.
Skip Nav Destination
e-mail: dagdas@yildiz.edu.tr
Article navigation
June 2007
Research Papers
Performance Analysis and Optimization of Double-Flash Geothermal Power Plants
Ahmet Dagdas
Ahmet Dagdas
Department of Mechanical Engineering,
e-mail: dagdas@yildiz.edu.tr
Yildiz Technical University (YTU)
, 34349, Besiktas, Istanbul, Turkey
Search for other works by this author on:
Ahmet Dagdas
Department of Mechanical Engineering,
Yildiz Technical University (YTU)
, 34349, Besiktas, Istanbul, Turkeye-mail: dagdas@yildiz.edu.tr
J. Energy Resour. Technol. Jun 2007, 129(2): 125-133 (9 pages)
Published Online: October 9, 2006
Article history
Received:
January 31, 2006
Revised:
October 9, 2006
Citation
Dagdas, A. (October 9, 2006). "Performance Analysis and Optimization of Double-Flash Geothermal Power Plants." ASME. J. Energy Resour. Technol. June 2007; 129(2): 125–133. https://doi.org/10.1115/1.2719204
Download citation file:
Get Email Alerts
Stage-wise kinetic analysis of ammonia addition effects on two-stage ignition in dimethyl ether
J. Energy Resour. Technol
Related Articles
Exergetic Performance Investigation of Varying Flashing From Single to Quadruple for Geothermal Power Plants
J. Energy Resour. Technol (December,2019)
Comparison of Thermodynamic Performances in Three Geothermal Power Plants Using Flash Steam
ASME Open J. Engineering (January,2022)
Retrofitting a Geothermal Power Plant to Optimize Performance: A Case Study
J. Energy Resour. Technol (December,1999)
Incorporating a District Heating/Cooling System Into an Existing Geothermal Power Plant
J. Energy Resour. Technol (June,1998)
Related Proceedings Papers
Related Chapters
Organic Rankine Cycle (Binary) Geothermal Power Plants
Geothermal Heat Pump and Heat Engine Systems: Theory and Practice
Martensitic 11% CrMoNiNb Steel for Turbine Rotors in Geothermal Power Stations
Steel Forgings: Second Volume
Engineering the Environment
Machines That Made History: Landmarks in Mechanical Engineering