This paper presents a method for estimating a hydraulic resistance multiplier to enable approximate values of friction coefficients to be calculated for turbulent flows in noncircular channels of arbitrary shape using correlations developed for the circular pipe. Unlike most other methods, no preknowledge on the flow channels, such as the laminar shape factor or characteristic length, is required. Good agreement between predictions using the new method and experiments was achieved.

1.
Kakac¸, S., Shah, R. K., and Aung, W., 1987, Handbook of Single-Phase Convective Heat Transfer, Wiley, NY.
2.
Lee
,
K. B.
,
1995
, “
Analytical Prediction of Subchannel Friction Factor for Infinite Bare Rod Square and Trianglar Arrays of Low Pitch to Diameter Ratio in Turbulent Flow
,”
Nucl. Eng. Des.
,
157
, pp.
197
203
.
3.
Vijayan
,
P. K.
,
Pilkhwal
,
D. S.
,
Saha
,
D.
, and
Raj
,
V. V.
,
1999
, “
Experimental Studies on the Pressure Drop Across the Various Components of a PHWR Fuel Channel
,”
Exp. Therm. Fluid Sci.
,
20
, pp.
34
44
.
4.
Gunn
,
D. J.
, and
Darling
,
C. W. W.
,
1963
, “
Fluid Flow and Energy Losses in Non-Circular Conducts
,”
Trans. Inst. Chem. Eng.
,
41
, pp.
163
173
.
5.
Rehme
,
K.
,
1973
, “
Simple Method of Predicting Friction Factors of Turbulent Flow in Non-Circular Channels
,”
Int. J. Heat Mass Transfer
,
16
, pp.
933
950
.
6.
Mala`k
,
J.
,
Hejna
,
J.
, and
Schmid
,
J.
,
1975
, “
Pressure Losses and Heat Transfer in Non-Circular Channels With Hydraulically Smooth Walls
,”
Int. J. Heat Mass Transfer
,
18
, pp.
139
149
.
7.
Bandopadhayay
,
P. C.
, and
Ambrose
,
C. W.
,
1980
, “
A Generalized Length Dimension for Non-Circular Ducts
,”
Lett. Heat Mass Transfer
,
7
, pp.
323
328
.
8.
Jones
, Jr.,
O. C.
,
1976
, “
An Improvement in the Calculation of Turbulent Friction in Rectangular Ducts
,”
ASME J. Fluids Eng.
,
98
, pp.
173
181
.
9.
Ahmed
,
S.
, and
Brundrett
,
E.
,
1971
, “
Characteristic Lengths for Non-Circular Ducts
,”
Int. J. Heat Mass Transfer
,
14
, pp.
157
159
.
10.
Miller, D. S., 1996, Internal Flow Systems, 2nd ed., BHR Group Limited, Bedfordshire, UK.
11.
Carlson
,
L. W.
, and
Irvine
,
T. F.
,
1961
, “
Fully Developed Pressure Drop in Triangular Shaped Corners
,”
ASME J. Heat Transfer
,
83
, pp.
441
444
.
12.
Mohandes
,
A.
, and
Knudsen
,
J. G.
,
1979
, “
Friction factors in Non-Circular Ducts With Sharp Corners
,”
Can. J. Chem. Eng.
,
57
, pp.
109
111
.
13.
France, J., Pardy, A., and Ellaby, G., 1971, “Friction Factor Measurements on a Hinkley ‘B’ AGR Interbrick Gas Coolant Passage,” AEA TRG Report 2002(R).
You do not currently have access to this content.