In this experimental study, the impact of suction chamber angle (SCA) on the entrainment ratio of a steam ejector refrigeration system (ERS) of 700 W was investigated. The basic dimensions of the ejector were derived from the compressible fluid flow equations using matlab. The system was tested with six different SCAs with various operating conditions, and its performance was analyzed. It is inferred that the entrainment of passive fluid from the evaporator is the strong function of the SCA. For all the active steam pressures, the entrainment of the passive fluid increases up to 12 deg of SCA, and above that the performance decreases significantly. Optimum angle of suction chamber increases the entrainment ratio for at least 49.96%. It is also found that the SCA has a minor influence on the back pressure.
Skip Nav Destination
Article navigation
January 2018
Research-Article
Experimental Studies on the Effect of Suction Chamber Angle on the Entrainment of Passive Fluid in a Steam Ejector
A. S. Ramesh,
A. S. Ramesh
Department of Mechanical Engineering,
St. Xavier's Catholic College of Engineering,
Nagercoil 629003, Tamil Nadu, India
St. Xavier's Catholic College of Engineering,
Nagercoil 629003, Tamil Nadu, India
Search for other works by this author on:
S. Joseph Sekhar
S. Joseph Sekhar
Department of Mechanical Engineering,
St. Xavier's Catholic College of Engineering,
Nagercoil 629003, Tamil Nadu, India
e-mail: josephsekhar@hotmail.com
St. Xavier's Catholic College of Engineering,
Nagercoil 629003, Tamil Nadu, India
e-mail: josephsekhar@hotmail.com
Search for other works by this author on:
A. S. Ramesh
Department of Mechanical Engineering,
St. Xavier's Catholic College of Engineering,
Nagercoil 629003, Tamil Nadu, India
St. Xavier's Catholic College of Engineering,
Nagercoil 629003, Tamil Nadu, India
S. Joseph Sekhar
Department of Mechanical Engineering,
St. Xavier's Catholic College of Engineering,
Nagercoil 629003, Tamil Nadu, India
e-mail: josephsekhar@hotmail.com
St. Xavier's Catholic College of Engineering,
Nagercoil 629003, Tamil Nadu, India
e-mail: josephsekhar@hotmail.com
1Corresponding author.
Contributed by the Fluids Engineering Division of ASME for publication in the JOURNAL OF FLUIDS ENGINEERING. Manuscript received March 24, 2017; final manuscript received August 10, 2017; published online October 4, 2017. Assoc. Editor: Moran Wang.
J. Fluids Eng. Jan 2018, 140(1): 011106 (8 pages)
Published Online: October 4, 2017
Article history
Received:
March 24, 2017
Revised:
August 10, 2017
Citation
Ramesh, A. S., and Joseph Sekhar, S. (October 4, 2017). "Experimental Studies on the Effect of Suction Chamber Angle on the Entrainment of Passive Fluid in a Steam Ejector." ASME. J. Fluids Eng. January 2018; 140(1): 011106. https://doi.org/10.1115/1.4037692
Download citation file:
Get Email Alerts
The Influence of Vortex Flow in the Dispersed Phase on Droplet Formation Dynamics
J. Fluids Eng (June 2025)
Related Articles
Visualization and Validation of Ejector Flow Field With Computational and First-Principles Analysis
J. Fluids Eng (May,2015)
A Simple and Fast Method for Calculating Properties Across a Condensation Shock
J. Fluids Eng (October,2018)
Effects of Surface Waviness on the Interaction of Oblique Shock Wave With Turbulent Boundary Layer
J. Fluids Eng (April,2018)
Nozzle Characteristics in High-Vacuum Flows—Rarefied Gas Dynamics
Trans. ASME (August,1952)
Related Proceedings Papers
Related Chapters
Scope of Section I, Organization, and Service Limits
Power Boilers: A Guide to the Section I of the ASME Boiler and Pressure Vessel Code, Second Edition
Lessons Learned: NRC Experience
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards
Development of Nuclear Boiler and Pressure Vessels in Taiwan
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 3, Third Edition