A gas-operated bearing damper for turbomachinery has been designed, analyzed, and experimentally investigated in the laboratory. The damper utilizes air bled off from the compressor to power an actuator through orifices with area modulated by the vibratory displacement at the bearing support. The design objective for this passive device is to make the actuating dynamic gas pressure phase lead the vibratory displacement by 90 deg. Several variations of the basic concept have been tested. An analysis was performed to guide the experiments. All of the designs tested to date can produce positive damping, and one particular design has produced a damping coefficient of 8756 N-s/m (50 lb-sec/in.) with a power penalty of 5.2 kW (7 hp) at 310 KPa (45 psi). This design was installed on a laboratory rotor with flexibly supported ball bearings, and significant damping of the critical speed response was demonstrated. The experimental results to date suggest that further research can produce significant improvements in performance, and the device appears to be especially adaptable to high-temperature applications for aircraft engines.
Skip Nav Destination
Article navigation
April 1993
Research Papers
A Gas-Operated Bearing Damper for Turbomachinery
J. M. Vance,
J. M. Vance
Texas A&M University, College Station, TX 77843
Search for other works by this author on:
B. P. Cardon,
B. P. Cardon
Texas A&M University, College Station, TX 77843
Search for other works by this author on:
L. A. San Andres,
L. A. San Andres
Texas A&M University, College Station, TX 77843
Search for other works by this author on:
A. F. Storace
A. F. Storace
General Electric Aircraft Engines, Cincinnati, OH 45215
Search for other works by this author on:
J. M. Vance
Texas A&M University, College Station, TX 77843
B. P. Cardon
Texas A&M University, College Station, TX 77843
L. A. San Andres
Texas A&M University, College Station, TX 77843
A. F. Storace
General Electric Aircraft Engines, Cincinnati, OH 45215
J. Eng. Gas Turbines Power. Apr 1993, 115(2): 383-389 (7 pages)
Published Online: April 1, 1993
Article history
Received:
March 4, 1991
Online:
April 24, 2008
Citation
Vance, J. M., Cardon, B. P., San Andres, L. A., and Storace, A. F. (April 1, 1993). "A Gas-Operated Bearing Damper for Turbomachinery." ASME. J. Eng. Gas Turbines Power. April 1993; 115(2): 383–389. https://doi.org/10.1115/1.2906720
Download citation file:
Get Email Alerts
Cited By
Image-based flashback detection in a hydrogen-fired gas turbine using a convolutional autoencoder
J. Eng. Gas Turbines Power
Fuel Thermal Management and Injector Part Design for LPBF Manufacturing
J. Eng. Gas Turbines Power
An investigation of a multi-injector, premix/micromix burner burning pure methane to pure hydrogen
J. Eng. Gas Turbines Power
Related Articles
Dynamic Response and Stability of Pressurized Gas Squeeze-Film Dampers
J. Vib. Acoust (January,1998)
Synchronous Response to Rotor Imbalance Using a Damped Gas Bearing
J. Eng. Gas Turbines Power (March,2010)
Dynamic Characteristics of the Diverging Taper Honeycomb-Stator Seal
J. Turbomach (October,2006)
Rotordynamic Force Coefficients of Pocket Damper Seals
J. Turbomach (October,2006)
Related Chapters
Introduction
Centrifugal Compressors: A Strategy for Aerodynamic Design and Analysis
Summary and Conclusions
Bearing Dynamic Coefficients in Rotordynamics: Computation Methods and Practical Applications
Introduction
Axial-Flow Compressors