Presented here is the second of a two-part investigation, designed to systematically identify and investigate the parameters affecting the evaporation from and boiling within, thin capillary wicking structures with a range of volumetric porosities and mesh sizes. The experimental studies were investigated under steady-state conditions at atmospheric pressure. Part I of the investigation described the wicking fabrication process and experimental test facility, and focused on the effects of the capillary wick thickness (ASME J. Heat Transfer., 128, pp. 1312–1319). In Part II, we examine the effects of variations in the volumetric porosity and the mesh size. The experimental results presented here indicate that the critical heat flux (CHF) was strongly dependent on both the mesh size and the volumetric porosity; while the evaporation/boiling heat transfer coefficient was significantly affected by mesh size, but not strongly dependent on the volumetric porosity. The experimental results further illustrate that the menisci at the CHF are located in the corners, formed by the wire and the heated wall and between the wires in both the vertical and horizontal directions. The minimum value of these three menisci determined the maximum capillary pressure generated through the capillary wick. The experimental results and observations are systematically presented and analyzed, and the local bubble and liquid vapor interface dynamics are examined theoretically. Based on the relative relationship between the heat flux and superheat, classic nucleate boiling theory, and the visual observations of the phase-change phenomena, as well as by combining the results obtained here with those obtained in Part I of the investigation, the evaporation/boiling heat transfer regimes in these capillary wicking structures are identified and discussed.
Skip Nav Destination
e-mail: lic4@rpi.edu
Article navigation
December 2006
This article was originally published in
Journal of Heat Transfer
Research Papers
Evaporation/Boiling in Thin Capillary Wicks (II)—Effects of Volumetric Porosity and Mesh Size
Chen Li,
e-mail: lic4@rpi.edu
Chen Li
Graduate Research Assistant
Rensselaer Polytechnic Institute
, Department of Mechanical, Aerospace and Nuclear Engineering Troy, NY 12180
Search for other works by this author on:
G. P. Peterson
G. P. Peterson
Professor and Chancellor
Search for other works by this author on:
Chen Li
Graduate Research Assistant
Rensselaer Polytechnic Institute
, Department of Mechanical, Aerospace and Nuclear Engineering Troy, NY 12180e-mail: lic4@rpi.edu
G. P. Peterson
Professor and Chancellor
J. Heat Transfer. Dec 2006, 128(12): 1320-1328 (9 pages)
Published Online: January 11, 2006
Article history
Received:
August 28, 2005
Revised:
January 11, 2006
Connected Content
This is a correction to:
Evaporation/Boiling in Thin Capillary Wicks (l)—Wick Thickness Effects
Citation
Li, C., and Peterson, G. P. (January 11, 2006). "Evaporation/Boiling in Thin Capillary Wicks (II)—Effects of Volumetric Porosity and Mesh Size." ASME. J. Heat Transfer. December 2006; 128(12): 1320–1328. https://doi.org/10.1115/1.2349508
Download citation file:
Get Email Alerts
Cited By
Related Articles
Evaporation/Boiling in Thin Capillary Wicks (l)—Wick Thickness Effects
J. Heat Transfer (December,2006)
Nucleate Boiling Comparison between Teflon-Coated Plain Copper and Cu-HTCMC in Water
J. Heat Transfer (August,2018)
Numerical Simulation of Evaporating Two-Phase Flow in a High-Aspect-Ratio Microchannel with Bends
J. Heat Transfer (August,2017)
Physics of the Microchannel Flow Boiling Process and Comparison With the Existing Theories
J. Heat Transfer (November,2017)
Related Proceedings Papers
Related Chapters
Energy Balance for a Swimming Pool
Electromagnetic Waves and Heat Transfer: Sensitivites to Governing Variables in Everyday Life
Post-CHF Heat Transfer in Flow Boiling
Two-Phase Heat Transfer
Critical Heat Flux in Flow Boiling
Two-Phase Heat Transfer