Detection of hard inclusions within soft tissue in robotic assisted minimally invasive surgery (MIS), also referred to as laparoscopic surgery, is of great importance, both in clinical and surgical applications. In clinical applications, surgeons need to detect and precisely identify the location and size of all growths, whether cancerous or benign, that are present within surrounding tissue in order to assess the extent and nature of any future treatment plan. In surgical applications, when any solid matter is being removed, it is important to avoid accidental injury to surrounding tissues and blood vessels since, were this to occur, it could then necessitate the need to resort to open surgery. The present study is aimed at developing a three-dimensional tactile display that provides palpation capability to any surgeon performing robotic assisted MIS. The information is collected from two force sensor/pressure matrices and processed with a new algorithm and graphically rendered. Consequently, the surgeon can determine the presence, location, and the size of any hidden superficial tumor/artery by grasping the target tissue in a quasi-dynamic way. The developed algorithm is presented, and the results for various configurations of embedded tumor/arteries inside the tissue are compared with those of the finite element analysis.

1.
Jemal
,
A.
,
Murray
,
T.
,
Ward
,
E.
,
Samuels
,
A.
,
Tiwari
,
R. C.
,
Ghafoor
,
A.
,
Feuer
,
E. J.
, and
Thun
,
M. J.
, 2005, “
Cancer Statistics
,”
Ca-Cancer J. Clin.
0007-9235,
55
, pp.
10
30
.
2.
Ries
,
L. A. G.
,
Harkins
,
D.
,
Krapcho
,
M.
,
Mariotto
,
A.
,
Miller
,
B. A.
,
Feuer
,
E. J.
,
Clegg
,
L.
,
Eisner
,
M. P.
,
Horner
,
M. J.
,
Howlader
,
N.
,
Hayat
,
M.
,
Hankey
,
B. F.
, and
Edwards
,
B. K.
, “
SEER Cancer Statistics Review 1975–2003
,” National Cancer Institute, http://seer.cancer.gov/csr/1975_2003http://seer.cancer.gov/csr/1975_2003
3.
Kuebler
,
B.
,
Gruber
,
R.
,
Joppek
,
Ch.
,
Port
,
J.
,
Passig
,
G.
,
Nagel
,
J. H.
, and
Hirzinger
,
G.
, 2009, “
Tactile Feedback for Artery Detection in Minimally Invasive Robotic Surgery—Preliminary Results of a New Approach
,”
IFMBE Proceedings
,
World Congress on Medical Physics and Biomedical Engineering
, September 7–12, Munich, Germany,
Springer
, Vol.
25
(
6
), pp.
299
302
.
4.
Miller
,
A. P.
,
Peine
,
W. J.
,
Son
,
J. S.
, and
Hammoud
,
Z. T.
, 2007, “
Tactile Imaging System for Localizing Lung Nodules During Video Assisted Thoracoscopic Surgery
,”
2007 IEEE International Conference on Robotics and Automation
, Rome, pp.
10
14
.
5.
Plunket
,
M. B.
,
Peterson
,
M. S.
,
Landreneau
,
R. J.
,
Ferson
,
P. F.
, and
Posner
,
M. C.
, “
Peripheral Pulmonary Nodules: Preoperative Percutaneous Needle Localization With CT Guidance
,”
Radiology
0033-8419,
185
(
1
), pp.
274
276
1992.
6.
Kawahara
,
T.
,
Toya
,
C.
,
Tanaka
,
N.
,
Kaneko
,
M.
,
Miyata
,
Y.
,
Okajima
,
M.
, and
Asahara
,
T.
, 2006, “
Non-Contact Impedance Imager With Phase Differentiator
,”
Proceedings of the First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics
, pp.
232
237
.
7.
Peine
,
W. J.
, 1998, “
Remote Palpation Instruments for Minimally Invasive Surgery
,” Ph.D. thesis, Harvard University, Boston.
8.
Dargahi
,
J.
,
Kahrizi
,
M.
,
Rao
,
N. P.
, and
Sokhanvar
,
S.
, 2006, “
Design and Microfabrication of a Hybrid Piezoelectric-Capacitive Tactile Sensor
,”
Sens. Rev.
0260-2288,
26
(
3
), pp.
186
192
.
9.
Dargahi
,
J.
, and
Najarian
,
S.
, 2004, “
Theoretical and Experimental Analysis of a Piezoelectric Tactile Sensor for Use in Endoscopic Surgery
,”
Sens. Rev.
0260-2288,
24
(
1
), pp.
74
83
.
10.
Takashima
,
K.
,
Yoshinaka
,
K.
,
Okazaki
,
T.
, and
Ikeuchi
,
K.
, 2005, “
An Endoscopic Tactile Sensor for Low Invasive Surgery
,”
Sens. Actuators, A
0924-4247,
119
, pp.
372
383
.
11.
Ramezanifard
,
M.
,
Sokhanvar
,
S.
,
Dargahi
,
J.
, and
Xie
,
W.
, 2008, “
Graphical Reproduction of Tactile Information of Embedded Lumps for MIS Applications
,”
Proceedings of IEEE Haptics Symposium
, pp.
247
252
.
12.
Sokhanvar
,
S.
,
Ramezanifard
,
M.
,
Dargahi
,
J.
, and
Packirisamy
,
M.
, 2007, “
Graphical Rendering of Localized Lumps for MIS Applications
,”
J. Med. Devices
1932-6181,
1
(
3
), pp.
217
224
.
13.
Kalantari
,
M.
,
Ramezanifard
,
M.
,
Ahmadi
,
R.
,
Dargahi
,
J.
, and
Kövecses
,
J.
, 2010, “
Design, Fabrication, and Testing of a Piezo-Resistive Sensor for Use in Minimally Invasive Surgery
,”
Proceedings of Haptics Symposium
, Waltham, MA, pp.
431
437
.
14.
Kalantari
,
M.
,
Dargahi
,
J.
,
Kövecses
,
J.
,
Ghanbari
,
M.
, and
Nouri
,
S.
, 2011, “
A New Approach for Modeling Piezoresistive Force Sensors Based on Semiconductive Polymer Composites
IEEE/ASME Trans. Mechatron.
1083-4435,
16
, pp.
1
10
.
15.
Baldewsing
,
R. A.
,
De Korte
,
C. L.
,
Schaar
,
J. A.
,
Mastik
F.
, and
Van der Steen
,
A. F. W.
, 2004, “
Finite Element Modeling and Intravascular Ultrasound Elastography of Vulnerable Plaques: Parameter Variation
Ultrasonics
0041-624X,
42
(
1–9
), pp.
723
729
.
16.
Chandran
,
K.
, 1992,
Cardiovascular Biomechanics
,
University Press
,
New York
.
17.
Mehrizi
,
A.
,
Najarian
,
S.
,
Moini
,
M.
, and
Ghomshe
,
F. T.
, 2008, “
Tactile Distinction of an Artery and a Tumor in a Soft Tissue by Finite Element Method
,”
Am. J. App. Sci.
,
5
, pp.
83
88
.
18.
Samani
,
A.
, and
Plewes
,
D.
, “
An Inverse Problem Solution for Measuring the Elastic Modulus of Intact Breast Tissue Tumours
,”
Phys. Med. Biol.
0031-9155,
52
, pp.
1247
2007.
19.
Najarian
,
S.
,
Dargahi
,
J.
, and
Mehrizi
,
A.
, 2009,
Artificial Tactile Sensing in Biomedical Engineering
,
McGraw-Hill
,
New York
.
20.
Ogden
,
R. W.
, 1984,
Non-Linear Elastic Deformation
,
Ellis-Horwood
,
Chichester, NY
.
21.
Mase
,
G. T.
, and
Mase
,
G. E.
, 1999,
Continuum Mechanics for Engineers
, 2nd ed.,
CRC
,
New York
.
22.
Freed
,
A. D.
, “
Natural Strain
,”
ASME J. Eng. Mater. Technol.
0094-4289,
117
(
4
), pp.
379
386
1995.
23.
Groot
,
E.
,
Hovingh
,
G. K.
,
Wiegman
,
A.
,
Duriez
,
P.
,
Smith
,
A. J.
,
Fruchart
,
J.
, and
Kastelein
,
J.
, “
Measurement of Arterial Wall Thickness as a Surrogate Marker for Atherosclerosis
,”
Circulation
0009-7322,
109
(
23
), pp.
33
38
2004.
24.
Heijnsdijk
,
E. A. M.
,
van der Voort
,
M.
,
De Visser
,
H.
,
Dankelman
,
J.
, and
Gouma
,
D. J.
, 2004, “
Slip and Damage Properties of Jaws of Laparoscopic Graspers
,”
Surg. Endosc
0930-2794,
18
(
6
), pp.
974
979
.
You do not currently have access to this content.