Characterizing the complexity of airflow limitation in diagnosing and assessing disease severity in asthma, COPD, cystic fibrosis, and other respiratory diseases can help guide clinicians toward the most appropriate treatments. Current technologies allow obstructive lung disease to be measured with about 5%−10% precision. A noninvasive dynamic pulmonary function monitor (DPFM) can quantify ventilation inhomogeneities, such as those originating in partially blocked or constricted small airways, with 1% precision if inert gas concentrations can be measured accurately and precisely over three to four decades of sensitivity. We have studied the precision and linearity of a commercially available mass spectrometer, sampling the gas exhaled by a mechanical lung analog, mimicking a multibreath inert gas washout measurement. The root mean square deviation of the inert gas concentration measured for each “breath,” compared to the expected value for a purely exponential decay, is found to be about 1.1% over three decades of concentration. The corresponding overall impairment, a specific measure of ventilation inhomogeneity, is found to be about 0.2%, which indicates that were inhomogeneities observed, the corresponding impairment could be measured with 1% precision.
Skip Nav Destination
Article navigation
June 2012
Research Papers
Development of a Non-Invasive Dynamic Pulmonary Function Monitor
Ralph J. Panos
Ralph J. Panos
Pulmonary, Critical Care and Sleep Division,Department of Internal Medicine,
University of Cincinnati
, Cincinnati, OH 45221;Pulmonary, Critical Care and Sleep Division,Cincinnati VAMC,Cincinnati, OH 45220e-mail:
Search for other works by this author on:
Larry Bortner
Ralph J. Panos
Pulmonary, Critical Care and Sleep Division,Department of Internal Medicine,
University of Cincinnati
, Cincinnati, OH 45221;Pulmonary, Critical Care and Sleep Division,Cincinnati VAMC,Cincinnati, OH 45220e-mail: J. Med. Devices. Jun 2012, 6(2): 021003 (10 pages)
Published Online: April 25, 2012
Article history
Received:
April 25, 2011
Revised:
February 17, 2012
Published:
April 24, 2012
Online:
April 25, 2012
Citation
Sokoloff, M. D., Bortner, L., and Panos, R. J. (April 25, 2012). "Development of a Non-Invasive Dynamic Pulmonary Function Monitor." ASME. J. Med. Devices. June 2012; 6(2): 021003. https://doi.org/10.1115/1.4006358
Download citation file:
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
Design of a Pressure Measuring Syringe
J. Med. Devices (June,2010)
Design of Pressurized Metered Dose Inhalers Modeling of Internal Flow and Atomization
J. Med. Devices (June,2010)
Numerical Modelling and Analysis of Peripheral Airway Asymmetry and Ventilation in the Human Adult Lung
J Biomech Eng (June,2012)
CRISIS Ventilator: Pilot Study of a Three-Dimensional-Printed Gas-Powered Resuscitator in a Porcine Model
J. Med. Devices (March,2022)
Related Chapters
Oscillatory Ventilation in the Treatment of Neonatal Respiratory Diseases
Biomedical Applications of Vibration and Acoustics in Therapy, Bioeffect and Modeling
Improving Prediction of Survival Using CT-Based Tumor Characteristics in Patients Treated for Metastatic Non-Small Cell Lung Cancer
Intelligent Engineering Systems through Artificial Neural Networks, Volume 20
Modeling Device Interaction with the Neonatal Lung
Medical Devices for Respiratory Dysfunction: Principles and Modeling of Continuous Positive Airway Pressure (CPAP)