The heat transfer characteristics of turbulent air flow in a two-pass channel were studied via the naphthalene sublimation technique. The test section, which consisted of two straight, square channels joined by a sharp 180 deg turn, resembled the internal cooling passages of gas turbine airfoils. The top and bottom surfaces of the test channel were roughened by rib turbulators. The rib height-to-hydraulic diameter ratio (e/D) was 0.063 and the rib pitch-to-height ratio (P/e) was 10. The local heat/mass transfer coefficients on the roughened top wall, and on the smooth divider and side walls of the test channel, were determined for three Reynolds numbers of 15,000, 30,000, and 60,000, and for three angles of attack (α) of 90, 60, and 45 deg. The results showed that the local Sherwood numbers on the ribbed walls were 1.5 to 6.5 times those for a fully developed flow in a smooth square duct. The average ribbed-wall Sherwood numbers were 2.5 to 3.5 times higher than the fully developed values, depending on the rib angle-of-attack and the Reynolds number. The results also indicated that, before the turn, the heat/mass transfer coefficients in the cases of α = 60 and 45 deg were higher than those in the case of α = 90 deg. However, after the turn, the heat/mass transfer coefficients in the oblique-rib cases were lower than those in the traverse-rib case. Correlations for the average Sherwood number ratios for individual channel surfaces and for the overall Sherwood number ratios are reported.
Skip Nav Destination
Article navigation
April 1988
Research Papers
Effect of Rib Angle on Local Heat/Mass Transfer Distribution in a Two-Pass Rib-Roughened Channel
P. R. Chandra,
P. R. Chandra
Turbomachinery Laboratories, Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843
Search for other works by this author on:
J. C. Han,
J. C. Han
Turbomachinery Laboratories, Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843
Search for other works by this author on:
S. C. Lau
S. C. Lau
Turbomachinery Laboratories, Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843
Search for other works by this author on:
P. R. Chandra
Turbomachinery Laboratories, Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843
J. C. Han
Turbomachinery Laboratories, Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843
S. C. Lau
Turbomachinery Laboratories, Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843
J. Turbomach. Apr 1988, 110(2): 233-241 (9 pages)
Published Online: April 1, 1988
Article history
Received:
February 6, 1987
Online:
November 9, 2009
Citation
Chandra, P. R., Han, J. C., and Lau, S. C. (April 1, 1988). "Effect of Rib Angle on Local Heat/Mass Transfer Distribution in a Two-Pass Rib-Roughened Channel." ASME. J. Turbomach. April 1988; 110(2): 233–241. https://doi.org/10.1115/1.3262186
Download citation file:
Get Email Alerts
Related Articles
Internal Cooling Near Trailing Edge of a Gas Turbine Airfoil With Cooling Airflow Through Blockages With Holes
J. Turbomach (July,2008)
Experimental and Numerical Study of Mass/Heat Transfer on an Airfoil Trailing-Edge Slots and Lands
J. Turbomach (April,2007)
Heat Transfer Enhancements in Rotating Two-Pass Coolant Channels With Profiled Ribs: Part 2—Detailed Measurements
J. Turbomach (January,2001)
Experimental and Numerical Cross-Over Jet Impingement in an Airfoil Trailing-Edge Cooling Channel
J. Turbomach (October,2011)
Related Proceedings Papers
Related Chapters
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Electrohydrodynamic Effect on Separation on an Airfoil in Low Reynolds Air Flow
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
Introduction
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration