A detailed two-component LDV mapping of the flow through a controlled diffusion compressor cascade at low Mach number ( ~ 0.25) and Reynolds number of about 7 × 105, at three inlet air angles from design to near stall, is reported. It was found that the suction-side boundary layer reattached turbulent after a laminar separation bubble, and remained attached to the trailing edge even at the highest incidence, at which losses were 3 to 4 times the minimum value for the geometry. Boundary layer thickness increased to fill 20 percent of the blade passage at the highest incidence. Results for pressure-side boundary layer and near-wake also are summarized. Information sufficient to allow preliminary assessment of viscous codes is tabulated.
Issue Section:
Research Papers
This content is only available via PDF.
Copyright © 1990
by The American Society of Mechanical Engineers
You do not currently have access to this content.